Máquina de ultrasonido Doppler de color portátil para órgano pequeño
$2100-3500 /Set/Sets
Tipo de Pago: | T/T |
Incoterm: | FOB |
Cantidad de pedido mínima: | 5 Set/Sets |
transporte: | Ocean,Land,Express,Air |
Hafen: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Tipo de Pago: | T/T |
Incoterm: | FOB |
Cantidad de pedido mínima: | 5 Set/Sets |
transporte: | Ocean,Land,Express,Air |
Hafen: | Shenzhen,Ningbo,Shanghai |
Modelo: MDK-680
Marca: Ultrasonido unido
Lugar De Origen: porcelana
Tipo De Poder: Electricidad
Servicio De Garantía: 1 año
Servicio Postventa: Repuestos gratis, Soporte técnico en línea
Material: metal, el plastico
Clasificación De Dispositivos Médicos: Clase II
Brand: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Color: black
Unidades de venta | : | Set/Sets |
Tipo de paquete | : | Caja de cartón |
Máquina de ultrasonido Doppler de color portátil para órgano pequeño (MDK-680)
En pequeños órganos, como la tiroides, la glándula mamaria y el globo ocular, el ultrasonido de color tiene una precisión diagnóstica obvia.
Desde cierto punto de vista, la sonda de 10MHz ha sido más clara que el Doppler en blanco y negro ordinario durante 5MHz, y la sonda es mucho más clara. El diagnóstico y el diagnóstico diferencial de las lesiones tiroideas se basan principalmente en el suministro de sangre interna de la tiroides, entre los cuales la imagen de hipertiroidismo es la más típica y específica.
El bocio simple no mostró un cambio significativo en comparación con el flujo sanguíneo de tiroides normal. La tiroiditis subaguda, la tiroiditis de Hashimoto entre los dos, se puede distinguir, y a través de los nódulos y la situación del flujo sanguíneo periférico puede ser un bocio nodular bien distinguido, adenoma tiroideo y cáncer de tiroides, por lo que se recomienda que el diagnóstico de tiroides no esté claro, el paciente tiene un Cierta capacidad económica puede hacer un ultrasonido de color diagnóstico.
El ultrasonido del color de mama se usa principalmente en el diagnóstico diferencial de fibroma mamario y cáncer de mama, y el globo ocular tiene un mejor valor en el diagnóstico de enfermedades vasculares del globo ocular.
Nuestros productos:
Escáner de ultrasonido en blanco y negro
Escáner de ultrasonido Doppler de color
Escáner de ultrasonido
No. |
Item |
Index |
<1> |
Depth |
≥300mm |
<2> |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<3> |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<4> |
Blind Area |
≤5 mm |
<5> |
Geometry Position Precision |
horizontal≤5% vertical≤5% |
<6> |
Language |
English/Chinese |
<7> |
Channels |
32 |
<8> |
Displayer |
12” LED |
<9> |
External Display |
PAL, VGA, USB |
<10> |
Gray Scale |
256 levels |
<11> |
Voltage |
AC220V ±10% |
<12> |
Operating System |
Windows 7 |
<13> |
Scanning Mode |
B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW |
<14> |
Probe |
Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion |
<15> |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
<16> |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
<17> |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
<18> |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
<19> |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
|
|
Basic measurement of M-mode: heart rate, time, distance and speed |
|
|
Doppler measurement: time, heart rate, speed, acceleration |